Question
What's new in the myQA Daily 1.3.2 software patch version?
Answer
Here is a list of new features and fixes for myQA Daily software 1.3.2:
- Directional symmetry produces fluctuations
Another ‘Mean Difference directional’ option have added to ‘Symmetry algorithm’ options under general settings to keeps the directional information and does not show the fluctuations. - Database size grows after upgrade
Database will become clean and compact after upgrade although at time of upgrade require space double of database space. - About mentions obsolete service email address
obsolete service email address has replaced with help center website link. Help center site can provide all latest contact addresses. - On task Executions approval, the lastCallTimeStamp does not get updated
Last Call Time Stamp have updated on task execution approval. Approval information can be fetched. - Expected center position of inline & crossline profiles should not be fixed to (0, 0)
In general settings new ‘Center Analysis option’ have been added. Changing the center analysis option will impact the displayed trend visualization. If Fixed at 0 is selected, the Center Inline and Crossline values will always be set to 0.0. If Taken from reference measurement is selected, the Center Inline and Crossline values from the Reference Measurement will be used. For all customers who update their system, the default selection for expected center position will be set to “Fixed at 0.” If preferred, you can change the Center Analysis setting back to “Taken from reference management” in the Settings menu. Please be mindful that if this is not adjusted after the update, it will affect how data is displayed in Trends. - Using 50% of Central axis signal to determine the field size for FFF beams
In general settings new ‘FFF - Field size algorithm’ option box has added with 2 options Inflection point and Full Width Half Maximum. Inflection point is used to normalize an FFF beam to the same dose level of an FF beam. In this case, the computed inflection point would represent the 50% dose level at the flattened beam profile. The values are obtained after scaling or normalizing the values to the 50% dose level using the average within the left and right inflection points. Full Width Half Maximum is Measured at 50% of the maximum value. - Performance breakdown for large database size and slow trends page
In some cases, it was observed that myQA Daily could become slow based on the number of parameters displayed in the trend page. Performance has improved on multiple levels like database level and application level. Trends and beams setup become fast from previous versions.
System Requirements myQA Daily 1.3.2
Operating System
myQA Daily can be installed on the following operating systems
Supported Operating Systems:
- Windows 10, 64 bit
- Windows 11, 64 bit
Supported Server Operating Systems:
Windows Server 2022
The server hosting the myQA Daily software needs to meet the following minimal criteria:
Minimum Hardware Requirements:
- Processor: Intel Core i5 desktop or mobile processor or better
- RAM of 4GB or more
- Ethernet minimum 10 Mbit
Or equivalent Virtual Runtime Environment
Supported Browsers and Resolution
Supported web browsers for client access
- Chrome 112+
- Firefox 112+
- Microsoft Edge 113+
- Note: Internet Explorer is not supported.
Mobile (Tablet) browsers
- Android Browser: Chrome Mobile 119+
- Apple Safari 16+
Minimum screen resolution is 1024x768 pixels.