Pre-filled Calibration Requests
Please find here some pre-filled calibration requests:
1. Chamber_FactoryCalibration_N(D,W).pdf
Choose this calibration request if you need a factory calibration (Dose to Water) for your chambers without electrometer. The factory calibration should be chosen if you want to use the chamber for relative dosimetry in water (e.g. scans in the phantom).
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
2. Chamber_FactoryCalibration_N(K).pdf
Choose this calibration request if you need a factory calibration (Air Kerma) for your chambers without electrometer. The factory calibration should be chosen if you want to use the chamber for relative dosimetry measurements in air (measurements in air in the phantom).
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
3. Chamber_SSDLCalibration_N(D,W).pdf
Choose this calibration request if you need a SSDL calibration (Dose to Water) for your chambers without electrometer. This SSDL calibration should be chosen if you want to use the chamber for absolute dosimetry measurements in water.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
4. Chamber_SSDLCalibration_N(K).pdf
Choose this calibration request if you need a SSDL calibration (Air Kerma) for your chambers without electrometer. This SSDL calibration should be chosen if you want to use the chamber for absolute dosimetry measurements in air.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
5. ChamberElectrometer_FactoryCalibration_N(D,W).pdf
Choose this calibration request if you need a factory calibration (Dose to Water) for your chambers with electrometer. The chamber and electrometer will be calibrated together as measurement system. This factory calibration should be chosen if you want to have a calibration factor for the chamber based on the electrometer. The measurement system (Dose 1 and chamber) should be used for relative dosimetry measurements in water.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
6. ChamberElectrometer_FactoryCalibration_N(K).pdf
Choose this calibration request if you need a factory calibration (Air Kerma) for your chambers with electrometer. The chamber and electrometer will be calibrated together as measurement system. This factory calibration should be chosen if you want to have a calibration factor for the chamber based on the electrometer. The measurement system (Dose 1 and chamber) should be used for relative dosimetry measurements in air.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
7. ChamberElectrometer_SSDLCalibration_N(D,W).pdf
Choose this calibration request if you need a SSDLcalibration (Dose to Water) for your chambers with electrometer. The chamber and electrometer will be calibrated together as measurement system. This SSDL calibration should be chosen if you want to have a calibration factor for the chamber based on the electrometer. The measurement system (Dose 1 and chamber) should be used for absolute dosimetry measurements in water.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
8. ChamberElectrometer_SSDLCalibration_N(K).pdf
Choose this calibration request if you need a SSDLcalibration (Air Kerma) for your chambers with electrometer. The chamber and electrometer will be calibrated together as measurement system. This SSDL calibration should be chosen if you want to have a calibration factor for the chamber based on the electrometer. The measurement system (Dose 1 and chamber) should be used for absolute dosimetry measurements in air.
Please do not forget to fill in the HV and Polarity that should be used. Before sending the request to us please sign the document online.
Attention
Please be informed that when calibrating two or more chambers with an electrometer the option Chamber and Electrometer as measurement system should not be used.
It will also be cheaper for you if you calibrate the chambers and electrometer individually.